Poslední aktualizace příspěvku

  • 03.10.2017 12:32
    Author of case changed 'Summary'.
  • 03.10.2017 12:32
    Author of case changed 'Steps taken'.
  • 03.10.2017 12:29
    Author of case changed description of this file.
  • 03.10.2017 12:28
    Author of case changed description of this file.
+0

Diagnostický případ

Opravené vozidlo
Martin/automeda net
Martin/automeda net
Jazyk případu:

Rev counter pointer flipped over

03.10.2017 | aktualizováno 22.02.2018 15:03:19 0 2455x

Informace o vozidle

VIN:
Výrobce: Ford
Model: Mondeo
Rok výroby: 2002
Kód motoru: 1,8
Typ motoru: RKK
Výkon (kW): 85 kW
Převodovka: Manuální
Palivo: Benzín
Najeto: 150 000 km

Jak se závada projevuje

Nefunguje / funguje nesprávně. Rev counter flipped over by 180°

Jak často se závada projevuje

  • Trvale přítomná závada.

V jakém systému se závada vyskytuje

  • Elektrorozvodu.
  • neukládá žádný chybový kód

Doposud provedeno bez úspěchu

The vehicle was sent to us from another workshop with a problem with the instruments. The owner does not want to have trouble buying second hand parts from a junk yard or with buying a complete new panel that is too expensive...

Závěr

VOZIDLO JSEM NEOPRAVOVAL

The instrument cluster on this model fails quite often due to problems with the processor. Since this vehicle has a problem only with one instrument the rev counter we can rule out a problem with the processor. The issue is a problem with the magnetic field that could be caused by a fault in the power supply, wiring or by a defective motor.
The initial testing of the motor revealed that the first coils resistance is 170 ohm and nothing was measured on the second coil. With a magnifying glass I could see a broken wire contact at the end. Soldered the joint and measured the same 170 ohm on the second coil. Reassembled everything and adjusted the pointer to idle value.
Vehicle repaired.

Obrázky, fotografie a soubory

Instrument cluster disassembly (7749/1)


Electric motor repair (7749/2)


Komentáře (0)